>
Tamil Nadu Common Entrance Test
List of top Questions asked in Tamil Nadu Common Entrance Test
The instruction XLAT in 8086 microprocessor is used to
TANCET - 2024
TANCET
Biomedical Engineering
Microprocessors
In 8085 microprocessor, two address lines namely A13 and A6 have become faulty and are stuck at logic 0. Which of the following address locations cannot be accessed in the memory?
TANCET - 2024
TANCET
Biomedical Engineering
Microprocessors
For the given 8086 microprocessor instructions below, which of the following is an invalid instruction?
TANCET - 2024
TANCET
Biomedical Engineering
Microprocessors
Consider a system output \( y(t) \) is related to its input \( x(t) \) as, \( y(t) = x(t) + \cos (x(t)) \). This system is
TANCET - 2024
TANCET
Biomedical Engineering
Signals and Systems
A continuous system is described by \( y(t) = x(t) \cos(200 \pi t) \). If \( x(t) \) is a two-tone signal with frequencies 25 Hz and 50 Hz, then the frequency components present in \( y(t) \) will be
TANCET - 2024
TANCET
Biomedical Engineering
Signals and Systems
Let a discrete time signal \( x(n) \) has Z-transform \( X(z) = \frac{1}{1+2 z^{-1}}, |z|>2 \). If its Fourier transform is denoted as \( X(e^{j\omega}) \), then
TANCET - 2024
TANCET
Biomedical Engineering
Signals and Systems
A single-tone real signal \( x[n] \) has its 8-point DFT denoted by \( X(k) \) which has \( X(2) = 2 \). Then, the signal \( x[n] \) will be equal to
TANCET - 2024
TANCET
Biomedical Engineering
Digital Signal Processing
The number of stages in radix-2 DIT FFT for \( N = 8 \) is
TANCET - 2024
TANCET
Biomedical Engineering
Digital Signal Processing
The minimum number of delay elements and multipliers required to implement a linear phase filter with impulse response \( h(n) \) defined for \( 0<n<8 \) are
TANCET - 2024
TANCET
Biomedical Engineering
Digital Signal Processing
In 1024-point DFT of a signal sampled at 8192 Hz, \( k = 8 \) corresponds to a frequency of
TANCET - 2024
TANCET
Biomedical Engineering
Digital Signal Processing
The width of the transition band of a linear phase band-pass FIR filter is given as \( 0.1 \pi \). The order of the filter designed using Blackman window is
TANCET - 2024
TANCET
Biomedical Engineering
Digital Signal Processing
Use Mason’s gain formula to find the transfer function of the given figure
TANCET - 2024
TANCET
Biomedical Engineering
Control Systems
The transfer function of the system is \( G(s) = \frac{100}{(s + 1)(s + 100)} \). For a unit step input, the approximate settling time for the 2 percent criterion is
TANCET - 2024
TANCET
Biomedical Engineering
Control Systems
The range of \( K \) for the stability of the system is \( 0<K<100 \). For \( K = 10 \), the gain margin of the system is
TANCET - 2024
TANCET
Biomedical Engineering
Control Systems
A Bode magnitude plot for the transfer function \( G(s) \) of a plant is shown below. Which one of the following transfer functions best describes the plant?
TANCET - 2024
TANCET
Biomedical Engineering
Control Systems
Which of the following techniques requires timing synchronization between transmitter and receiver?
TANCET - 2024
TANCET
Biomedical Engineering
Communication System
If a uniform quantizer with sinusoidal input signal produces the output SNR of 43.76 dB, determine the number of quantization levels used.
TANCET - 2024
TANCET
Biomedical Engineering
Communication System
An AM modulator develops an unmodulated power of 400 W and power of 450 W when modulated with modulation index \( \mu \) across the resistive load. Then the value of \( \mu \) is
TANCET - 2024
TANCET
Biomedical Engineering
Communication System
If a discrete memory-less source emits symbols with probabilities 0.2, 0.2, 0.2, 0.2, and 0.2, determine the entropy of the source.
TANCET - 2024
TANCET
Biomedical Engineering
Communication System
Respiration rate is measured using —————.
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Instrumentation
The impedance of Biopotential electrode is ————— at high frequency.
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Instrumentation
Muscle artifacts in ECG signals are eliminated using —————.
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Instrumentation
The greatest volume of gas that can be inspired by voluntary effort after maximum expiration is —————.
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Instrumentation
In surgical diathermy when the needle point electrodes are stuck into the tissue and kept steady. This refers to:
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Equipments
Which of the following are the requirements for a single channel ECG telemetry system?
TANCET - 2024
TANCET
Biomedical Engineering
Biomedical Equipments
Prev
1
...
27
28
29
30
31
...
59
Next