Telangana State Post Graduate Engineering Common Entrance Test
>
Instrumentation Engineering
List of top Instrumentation Engineering Questions asked in Telangana State Post Graduate Engineering Common Entrance Test
Match the device with its working principle:
List-1
List-2
a. Bourdon gauge
V. Deformation of element
b. Pirani gauge
I. Thermal conductivity
c. Semiconductor strain gauge
III. Piezo resistive effect
d. Bi-metallic strip
II. Thermal coefficient of expansion
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Transducers for industrial instrumentation
Match the instruments with the parameters they measure:
List-1
Instrument
List-2
(Parameter)
A
Autocollimeter
\( \text{Angular error} \)
B
Hygrometer
\( \text{Humidity} \)
C
Nephelometer
\( \text{Density} \)
D
Mass spectrometer
\( \text{Molecular weight} \)
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Transducers for industrial instrumentation
A standard three-lead frontal plane ECG is taken from a person with a normal heart. The peak amplitude of R wave is
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
The treadmill test is used to diagnose
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
In an electromagnetic blood flow meter, the induced voltage is directly proportional to the
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
The Geiger counter has high quantum efficiency in the wavelength range of
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
Korotkoff sounds are used
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
In the standard 12-lead ECG recording system, the minimum number of electrodes required to be attached to the human subject for recording any one of the unipolar chest lead signals is
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
Gas chromatography is used for
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Transducers for industrial instrumentation
IR spectroscopy
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Biomedical Instrumentation
A psychrometric chart is used to determine
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Transducers for industrial instrumentation
The breakaway point of the root locus on the real axis for a closed loop system with a loop gain \( G(s) = \frac{K(s+10)}{(s+2)(s+5)} \) is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
The phase margin of the system for which the loop gain \( GH(j\omega) = \frac{A_1}{(j\omega + 1)^3} \) is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
The coherence length of the He-Ne laser beam is 120 cm. Its coherence time in seconds is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
An optical fiber is characterized by
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
Collimated light beams from a He-Ne laser and a sodium vapor lamp are focused using a lens.
The size of the spot at the focal point due to the laser is relatively smaller because
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
A step index optical fiber whose refractive indices of the core and cladding are 1.44 and 1.40 respectively, is surrounded by air. Its numerical aperture is
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
An optical fiber has a refractive index of 1.641 for the core and 1.422 for the cladding.
The critical angle above which a ray will be totally internally reflected is
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
Consider a unity feedback control system whose forward path transfer function is \( G(s) = \frac{K}{s^2} \). The steady state error for a step input is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
If the transfer function of a system is \( G(s) = \frac{A}{s^2 + \omega^2} \), then the steady state gain of the system to a unit step input is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
An integral controller is used to:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
The transfer function between \( y_2 \) and \( y_1 \) in the figure shown is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Block diagrams and Signal flow graphs
A first order system with a proportional controller exhibits an offset to step input. The offset can be reduced by:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
The system \( G(s) = \frac{0.8}{s^2 + s - 2} \) is subjected to a step input. The system output \( y(t) \) as \( t \rightarrow \infty \) is:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
A temperature control system is usually very sluggish. To improve its dynamics:
TS PGECET - 2024
TS PGECET
Instrumentation Engineering
Control Systems
Prev
1
2
3
...
5
Next