CUET (PG)
>
Electrical and Electronic Measurements
List of top Electrical and Electronic Measurements Questions asked in CUET (PG)
PIV of a SCR is 650V. Find out the required Voltage if the safety factor is 2.
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
The circuit shown in the figure will work as____
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
What is the maximum output voltage of a 3-ph bridge rectifier supplied with line voltage of 440V?
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
A buck regulator has an input voltage of 16V and the required output voltage is 4V. What is the duty cycle of the regulator?
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
The classification of transmission lines (T.L)as short. Medium & Long T.L is based upon__
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
An Op-amp has a slew rate of 5V/us. The largest sine wave output voltage possible at a frequency of 1MHz is____
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
Given below are two statements:
Statement I: The speed of an induction motor can not be continued as easily and efficiently as that of a de shunt motor.
Statement II: Slip of an induction motor can not be changed by varying the voltage applied to the stator
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
A 0 to 200V Voltmeter has a accuracy of 1% of full scale reading. The voltage measure by this instrument is 50V. What is limiting error?
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
Which displacement transducer is used for accurate and linear measurement?
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
The overall gain
\(\frac{C(S)}{R(S)}\)
of the block diagram shown below is
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
The maximum possible speeds in rpm at which an alternators can be driven to generate voltages at 60 Hz and 50 Hz are, respectively:
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage
Assume the incremental cost characteristics of two generates delivering 250MW as.
\(\frac{dF_1}{dP_1} = 20 +0.01P_1\)
\(\frac{dF_2}{dP_2} = 14 +0.2P_1\)
For economic operation, the generation P
1
and P
2
should be:
CUET (PG) - 2023
CUET (PG)
Electrical and Electronic Measurements
Measurement of voltage